| purchasing |
عربي |
| Tender NO |
Tender Name |
| Last date for submission of bid offer |
Bid Opening |
Value |
| Day |
Time |
Date |
Day |
Time |
Date |
| HA/R/E/049 |
SUPPLY INSTALLING OPERATION AND TESTING FOR THE FOLLOWING ITEMS 1 QUANTITY REQUIRED THREE NO OF HIGH PRESSURE PUMPS 2 QUANTITY REQUIRED THREE NO OF ENERGY RECOVER TURBINE 3 QUANTITY REQUIRED TWO NO OF SEAWATER PUMPS REMOVING OPERATION AND TESTING NEW COMPLIANCE PUMPS
|
| Monday |
9:0 |
27/5/2013 |
Monday |
10:0 |
27/5/2013 |
500 |
|
| Y/M/P/0093 |
Rehabilition & Upgradation of HFO Handling Systems for Phase-I & II at SWCC Yanbu Plants
|
| Tuesday |
9:0 |
28/5/2013 |
Tuesday |
10:0 |
28/5/2013 |
500 |
|
| KH/R/E/13 |
Replace the Main two Generators Transformer in Al KHOBAR Plant - Phase 2
|
| Wednesday |
9:0 |
29/5/2013 |
Wednesday |
10:0 |
29/5/2013 |
1000 |
|
| SQ/R/M/726 |
SUPPLY & REPLACEMENT OF PIPING ON SA SYSTEM TO ABHA RESERVIOR AT SWTF-SHUQAIQ
|
| Saturday |
9:0 |
1/6/2013 |
Saturday |
10:0 |
1/6/2013 |
500 |
|
| SQ/M/M/710 |
the supply & replacement of main air heater assembly at unit # 1&2 of shuqaiq plant
|
| Sunday |
9:0 |
2/6/2013 |
Sunday |
10:0 |
2/6/2013 |
500 |
|
| 2013/ت |
2013 (Property all risks swcc Insurance policies tender policy motor comprehehensive policy marin Hull policy Marin cargo policy marin cargo By Post Policy
|
| Monday |
9:0 |
3/6/2013 |
Monday |
10:0 |
3/6/2013 |
500 |
|
| SQ/RM/792 |
REHABITATION & OVERHHOUL OF 20 MAIN PUMPS & BOOSTER PUMPS AT PUMPING STATINS 1.2.3&4 OF SHUQAIAQ PIPELINES (SWTF)
|
| Monday |
9:0 |
3/6/2013 |
Monday |
11:0 |
3/6/2013 |
500 |
|
| KH/R/M/315 |
REPAIR/ REFURBISH HP PRE-HEATERS 2 NOS.INCLUDING TUBES RELACEMENT AI AL-KHOBAR PLANTS (AK2/AK3)
|
| Tuesday |
9:0 |
4/6/2013 |
Tuesday |
10:0 |
4/6/2013 |
1000 |
|
| SH/R/E/722 |
REHABILTAION OF HV RELAY & PROTECTION SYSTEM FOR 110 KV HV SUBSTATION IN MPS2.MPS3 AND MP4 PUMP STATION SHOIBA PLANTS_PIPELINES
|
| Wednesday |
9:0 |
5/6/2013 |
Wednesday |
10:0 |
5/6/2013 |
1000 |
|
| Y/E/G/0011 |
Supply and Replacement of 03 Nos (Three) Elevators at SWCC Yanbu Phase II Plant
|
| Saturday |
9:0 |
8/6/2013 |
Saturday |
10:0 |
8/6/2013 |
1000 |
|
| JB/R/E/430 |
REPLACEMENT OF UNIT TRANSFORMERS AT JUBAIL PHASE-1 PLANTS
|
| Sunday |
9:0 |
9/6/2013 |
Sunday |
10:0 |
9/6/2013 |
500 |
|
| MT-682 |
Rehabilitation Of Electrostatic Precipitator And The Conveyor System At Shoaiba Ph-1 Plants
|
| Monday |
9:0 |
10/6/2013 |
Monday |
10:0 |
10/6/2013 |
1000 |
|
| KH/R/M//345 |
Life Assessment Of The Boiler Unit No 3 At Khobar Ph-2 Plants To Determine Its Remaining Life & Preparing Scope of Work For Extending Its Life By 15 Years
|
| Tuesday |
9:0 |
11/6/2013 |
Tuesday |
10:0 |
11/6/2013 |
1000 |
|
| JB/R/I/277 |
Replacement of Field Instruments From The Common System & Blending Station Areas At Jubail Phase-1 Plants
|
| Wednesday |
9:0 |
12/6/2013 |
Wednesday |
10:0 |
12/6/2013 |
500 |
|
| |
PROVIDING PC,s FOR WEST AND EAST PLANTS
|
| Saturday |
9:0 |
15/6/2013 |
Saturday |
10:0 |
15/6/2013 |
1000 |
|
| 2700/507 |
SHIFT THE SWITCH GEAR PANELS AND ALL AUXILIARIES LIKE BATTERY CHARGER ETC., FROM AL-WAJH OLD PLANT AREA TO THE NEW SWGR BUILDING IN THE NEW PLANT AREA
|
| Sunday |
9:0 |
16/6/2013 |
Sunday |
10:0 |
16/6/2013 |
500 |
|
| Y/M/P//0089 |
Complete Major Overhauling & Life Assessment Of Steam Turbine Generator Unit Nos 2,3&5 At Phase-1 Of Yanbu Madina Desal & Power Plants
|
| Monday |
9:0 |
17/6/2013 |
Monday |
11:0 |
17/6/2013 |
500 |
|
| MT-711 |
REHABILITATION OF HV AC EQUIPMENTS IN SHOAIBA PLANTS PH_2
|
| Tuesday |
9:0 |
18/6/2013 |
Tuesday |
10:0 |
18/6/2013 |
1000 |
|
| Y/M/P/0084 |
SCOPE OF WORK FOR UP GRADAATION & MAJOR OVERHAULING OF STEAM TURBINE GENERATOR UNIT NO 6 AT PHASE-II OF SWCC YANBU DESALINATION AND POWER PLANTS
|
| Wednesday |
9:0 |
19/6/2013 |
Wednesday |
11:0 |
19/6/2013 |
500 |
|
| JB-R-M-1044 |
Re-Tubing of 1st Stage Desal Condensers & Other Rehabilitation Works of Jubail Phase-2B C-4 Desalination Units 21-30
|
| Saturday |
9:0 |
22/6/2013 |
Saturday |
10:0 |
22/6/2013 |
500 |
|
| MT-718 |
REPLACEMENT OF BALL CLEANING SYSTEM AND SEA WATER SCREENING SYSTEM CONTROLS FOR PH-1&2
|
| Sunday |
9:0 |
23/6/2013 |
Sunday |
10:0 |
23/6/2013 |
500 |
|
| Y/M/P/0087 |
SCOPE OF WORKS FOR COMPLETE REPLACEMENT OF LP STEAM BYPASS SYSTEM ATTEMPERATOR UNITS ON UNITS NO 1.2.3.4.5 OF SWCC PLANT PHASE-1
|
| Monday |
9:0 |
24/6/2013 |
Monday |
10:0 |
24/6/2013 |
500 |
|
| Y/M/D/0063 |
SCOPE OF WORK FOR COMPLETE OVERHAULING OF FIFTEEN HIGH PRESSURE FEED PUMPS WITH SUPPLYING AND REPLACING OF SPARES .AT RO PLANT OF MEDINA-YANBU DESALINATION AND POWER PLANTS
|
| Wednesday |
9:0 |
26/6/2013 |
Wednesday |
10:0 |
26/6/2013 |
500 |
|
| SQ/M/M/729 |
The Rehabilitation of ESP (1 & 2) at SHUQAIQ Plant
|
| Wednesday |
9:0 |
3/7/2013 |
Wednesday |
10:0 |
3/7/2013 |
500 |
|
| FA/R/M/046 |
REHABILITATION WATER PRODUCTION TANK TK-100B TO REPLACE BOTTOM PLATES AND ANNULAR WITH PAINTING AND REPLACING INTERNAL/EXTERNAL CATHODIC PROTECTION SYSTEM AT FARASAN PLANT
|
| Saturday |
10:0 |
6/7/2013 |
Saturday |
11:0 |
6/7/2013 |
500 |
|
| JD/RC/898 |
TO PROVIDE THE NECESSAY SPECIALIZED SERVICE TO REHABILITION THE OUTFALL OF JEDDAH (3&4( AREA BY CONSTRUCT SUPPORTING WALLS IN & FIXING THE OIL BOOMS IN IT FOR PROHIBITING OIL LEAKAGE TO SEA WATER
|
| Sunday |
9:0 |
18/8/2013 |
Sunday |
10:0 |
18/8/2013 |
500 |
|
| JD/RG/897 |
THE REHABILITATION AND RECONSTRUCTION OF THE ISOLATION OF VARIOUS SIZES AND HOSE REEL HOSE AND RND REPLACE THE HOSES FIRE FIGHTING
|
| Monday |
9:0 |
19/8/2013 |
Monday |
10:0 |
19/8/2013 |
500 |
|
| SH/R/E/749 |
REWINDING OF MOTOR No.(21) 13.8 KV at MINA STAATION IN PIPELINES SHOAIBA PLANTS
|
| Tuesday |
9:0 |
20/8/2013 |
Tuesday |
10:0 |
20/8/2013 |
500 |
|
| HA/R/E/054 |
SUPPL Y/INSTALLING AND TESTING FOR (FOUR) NO OF ELECTRICAL MOTORS USE FOR HIGH PRESSURE PUMP / WITH ENERGY RECOVER TURBINE (AS DRIVE MOTOR
|
| Wednesday |
9:0 |
21/8/2013 |
Wednesday |
10:0 |
21/8/2013 |
500 |
|
| RW/R/I/311 |
RETS LINE AB LOW VOLTAGE CONTROL CABLE REHABILTATION AT HPT
|
| Saturday |
9:0 |
24/8/2013 |
Saturday |
10:0 |
24/8/2013 |
500 |
|
| Y-P-I-0044 |
REPLACEMENT / UP GRADATION OF HYDRAULIC POWER PACK & ASSOCIATED CONTOL SYSTEM OF MOKVELD VALVES (FCV/PCV) IN YANBU-MEDINA PIPELINES PHASE II
|
| Sunday |
9:0 |
25/8/2013 |
Sunday |
10:0 |
25/8/2013 |
1000 |
|
| Y/E/G/0080 |
SALINE WATER CONVERSION CO RPORATION YANDU MEDINA POWER AND DESALINATION PLANTS SCOPE OR WORK FOR THE OVERHAULING OF 380 KV GAS INSULATED SUD STATION PHASE I
|
| Monday |
9:0 |
26/8/2013 |
Monday |
10:0 |
26/8/2013 |
500 |
|
| Y/E/G/0084 |
Specifications for Supply, Installation, Testion and Commissioning of New Compatible Refrigeration Units in Place of Existing Old Refrigeration Units (08 Nos) for CO2 Storage Tanks in Chemical Storage Building at SWCC-Yanbu Plant(Phase-l) of Saline Water Conversion Corporation
|
| Tuesday |
9:0 |
27/8/2013 |
Tuesday |
10:0 |
27/8/2013 |
500 |
|
| |
PROJECT CONSTRUCTION FOR PROJECT OF EXECUTION A SECURITY FENCE AROUND SWCC LANDS
|
| Saturday |
9:0 |
31/8/2013 |
Saturday |
10:0 |
31/8/2013 |
5000 |
|
| YM/R/I/129 |
REHABILITATION AND REPLACEMENT OF ALL FUEL CONTROL AND SHUTOFF VALVES IN BOILER 6 & 7 IN PH-II PLANTS
|
| Sunday |
9:0 |
1/9/2013 |
Sunday |
10:0 |
1/9/2013 |
500 |
|
| MT-716 |
rehabilitation of buidings social and sports clubs in housing shuaiba plant
|
| Wednesday |
9:0 |
4/9/2013 |
Wednesday |
10:0 |
4/9/2013 |
500 |
|
| JB/R/I/278 |
Upgrading/Replacement of Critical Actuators With Accessories/Critical Valves with Actuators & All Its Accessories At Jubail Ph 2A/B Desal Units & lntakes C1-C5
|
| Saturday |
9:0 |
7/9/2013 |
Saturday |
10:0 |
7/9/2013 |
500 |
|
| -- |
pest control project in the east west coasts and housing complexes affiliate
|
| Sunday |
9:0 |
8/9/2013 |
Sunday |
10:0 |
8/9/2013 |
1000 |
|